Euphonix MADI Converters Operation Manual DM714 and MD704 Converters
24
3.4 DM714 Rear Panel
Figure 3-2 DM714 Rear Panel
Input Voltage Selector: This red switch allows the unit to operate in either 110/
115 VAC or 220/230/240 VAC environments. A fuse must also be changed for 220/
230/240 VAC operation (see page 6). Units are shipped set and fused for 110/115 VAC.
Power Connector (IEC) and Fuse Tray: The IEC power connector accepts standard
IEC power cords. The fuse tray contains both the active fuse and a spare fuse for 220/
230/240 VAC operation. See page 6 for instructions on how to change the fuse for 220/
230/240 VAC operation.
AES/EBU Digital Inputs (female XLR): 12 AES/EBU stereo inputs.
Parallel AES/EBU Digital Inputs (female DB25): Three 8-channel digital connectors
function in parallel with XLR digital inputs, and should not be used simultaneously
with the XLR inputs. See Figure 3-4 on page 32 for pinout diagram.
Auxiliary Analog Inputs (female XLR): Two balanced analog inputs on XLR connec-
tors. Input sensitivity is set from the front panel.
Auxiliary AES/EBU Digital Input (female XLR): Stereo AES/EBU digital input on
one XLR connector. Functions in parallel with the auxiliary S/PDIF input and the two
inputs should not be used simultaneously.
Auxiliary S/PDIF Digital Input (RCA): Stereo S/PDIF digital input on one RCA con-
nector. Functions in parallel with the auxiliary AES/EBU input and the two inputs
should not be used simultaneously.
AES Sync In (female XLR): Master clock input for the converter when using AES as
Sample Rate Source.
AES Sync Thru (male XLR): Outputs the same signal connected to AES Sync In.
Word In (BNC): Master clock input for the converter when using Word Clock as
Sample Rate Source.