Installation Instructions

1.Using the supplied screws, mount the bracket base on the desired location.

2.Connect the BNC connector of the camera to a monitor or other video device through a 75 ohm type coaxial cable with BNC female connector at cable extension.

3.Connect the 24VAC or 12VDC regulated power source of the camera (power jack) to the power-in jack with 2mm plug. For 12VDC power source, please make sure the power plug is center+ outer- for heater normal operation.

4.Our factory settings is for you to get the best image within about 3~5 meters (for veri-focal lens f=3.5~8mm) or 5~10 meters (for veri-focal lens f=9~22mm) . If it is out of focus, or any other adjustment is required, follow the procedures below.

a.Remove the fixing screw in the front, which hold the sun shield cover. Remove the sun shield cover.

b.Twist open and carefully remove the housing cover.

(Please pay attention to prevent damage to the “O”-Ring seal.)

c.Loosen the focal lens and focus locking screws.

d.Adjust the lens to bring the subject into focus.

(Caution: Heater elements could be hot! When camera power is on, use caution when adjusting the camera.)

e.Retighten the screws.

f.Please refer to the Settings section for the details of the other adjustments. Adjust accordingly if necessary.

5

Page 8
Image 8
EverFocus EZ180 user manual Installation Instructions