EXCELL PRECISION CO., LTD.

2Internal Function Parameter Description

Parameter

Function

 

Setting

Default

Code

Parameter

Description

Setting

 

CFN-00

CFN-01

CFN-02

CFN-03

CFN-04

CFN-05

Tare or Zero

0

ON

0

Function under

1

OFF

Unstable Status

 

 

 

 

Re-zeroing after

0

OFF

0

Turning on

1

ON

 

 

 

 

 

 

 

 

 

0%: Full range re-zero

 

Re-zero Range

0% ~ 30%

1% ~ 30%:

0

 

 

Capacity × ± setting value%

 

Filter Strength

0 ~ 5

Strength increases by number

2

 

 

 

 

 

0

No limit

 

AD Sampling

1

20 times/sec.

2

Rate

2

10 times/sec.

 

 

3

5 times/sec.

 

 

0

OFF

 

Animal Scale

1

Mode 1: No weight display

0

under unstable status

Mode

 

 

 

 

2Mode 2: Weight display whether under stable or unstable status

CFN-06

Animal Scale

0 ~ 100

Mode 2: Stable Range Setting

30

Stable Range

 

 

 

 

 

 

0

8 times

 

 

Animal Scale

1

16 times

 

CFN-07

Sampling

2

32 times

2

 

Frequency

3

64 times

 

 

 

 

 

 

4

128 times

 

CFN-08

Dual Range

0

Multi-interval

0

Resolution

1

Multi-range

 

Setting

 

 

Dual Range

 

 

 

CFN-09

Resolution

0 ~ 65535

 

5000

Middle Point

 

 

 

 

 

Setting

FM User Manual