DANGER

Jump starting a weak battery that is cracked, frozen, has low electrolyte level, or an open/shorted battery cell, can cause an explosion resulting in serious personal injury.

Do Not jump start a weak battery if these conditions exist.

2.Make sure the booster is a good and fully charged lead acid battery at 12.6 volts or greater. Use properly sized jumper cables (4 to 6 AWG) with short lengths to reduce voltage drop between systems. Make sure the cables are color coded or labeled for the correct polarity.

CAUTION

Connecting the jumper cables incorrectly (wrong polarity) can immediately damage the electrical system.

Be certain of battery terminal polarity and jumper cable polarity when hooking up batteries.

Note: The following instructions are adapted from the SAE J1494 Rev. Dec. 2001 – Battery Booster Cables – Surface Vehicle Recommended Practice (SAE – Society of Automotive Engineers).

WARNING

Batteries contain acid and produce explosive gases.

Shield the eyes and face from the batteries at all times.

Do Not lean over the batteries.

Note: Be sure the vent caps are tight and level. Place a damp cloth, if available, over any vent caps on both batteries. Be sure the vehicles do not touch and that both electrical systems are off and at the same rated system voltage. These instructions are for negative ground systems only.

3.Connect the positive (+) cable to the positive (+) terminal of the discharged battery that is wired to the starter or solenoid as shown in Figure 30.

Figure 30

1.Positive (+) cable on discharged battery

2.Positive (+) cable on booster battery

3.Negative (–) cable on the booster battery

4.Negative (–) cable on the engine block

5.Booster battery

6.Discharged battery

7.Engine block

4.Connect the other end of the positive cable to the positive terminal of the booster battery.

5.Connect the black negative (–) cable to the other terminal (negative) of the booster battery.

6.MAKE THE FINAL CONNECTION ON THE ENGINE BLOCK OF THE STALLED VEHICLE (NOT TO THE NEGATIVE POST) AWAY FROM THE BATTERY. STAND BACK.

7.Start the vehicle and remove the cables in the reverse order of connection (the engine block (black) connection is the first to disconnect).

Installing the Battery

1.Position the battery in the tray with the terminal posts toward the operating position (Figure 29).

2.Install the positive (red) battery cable to the positive (+) battery terminal using the fasteners removed previously.

3.Install the negative battery cable to the negative (-) battery terminal using the fasteners removed previously.

4.Slide the red terminal boot onto the positive (red) battery post.

5.Secure the battery with the strap (Figure 29).

38

Page 38
Image 38
Exmark 4501-191 Rev.A manual Installing the Battery, Do Not jump start a weak battery if these conditions exist

4501-191 Rev.A specifications

The Exmark 4501-191 Rev.A is a cutting-edge lawn mower designed to deliver exceptional performance and efficiency for both residential and commercial users. With its robust build and advanced technology, this model has quickly gained popularity among landscapers and homeowners alike.

One of the standout features of the Exmark 4501-191 Rev.A is its powerful engine. Equipped with a high-performance Kohler engine, this mower provides ample horsepower and torque, ensuring efficient cutting even in tough conditions. This allows users to tackle dense grass and uneven terrains with ease, making it ideal for various landscaping needs.

The mower's innovative cutting system is another highlight that sets it apart. Featuring a large, durable cutting deck, the Exmark 4501-191 Rev.A offers an impressive cutting width, enabling users to cover more ground in less time. The deck is designed for precision, providing a clean and even cut every time. Additionally, the adjustable cutting height feature allows for customized lawn care, accommodating different grass types and lengths.

One of the remarkable technologies integrated into the Exmark 4501-191 Rev.A is its efficient fuel system. The mower is engineered to maximize fuel efficiency, allowing users to extend their mowing sessions without the frequent need to refuel. This feature not only saves time but also reduces overall operating costs, making the mower a cost-effective choice for users with large properties.

Comfort and maneuverability are also key characteristics of the Exmark 4501-191 Rev.A. The ergonomic controls are designed for ease of use, providing a smooth and responsive experience. The mower features large rear wheels and front casters, allowing for agile navigation around obstacles and tight spaces. This is particularly beneficial for commercial users who often work in complex environments.

Maintenance is simplified with the Exmark 4501-191 Rev.A, allowing users to focus on lawn care rather than upkeep. The model is built with durable materials, ensuring longevity and reducing wear and tear. Clear access points for cleaning and maintenance further enhance user convenience, making it easy to keep the mower in top shape.

In summary, the Exmark 4501-191 Rev.A is a high-performance lawn mower that combines power, efficiency, and ease of use. With its advanced engine, innovative cutting system, and user-friendly design, it stands out as an excellent choice for anyone looking to achieve a beautifully manicured lawn. Whether for commercial or residential use, this mower is a reliable tool that promises exceptional results.