Chapter 2 Hardware Installation and Service 2-7
2.2.2.1 Verify Chassis Fan Tray Upgrade
Caution – The Sun Netra CT 900 server fan tray upgrade kit (594-4953) must be
installed in the chassis before the Sun Netra CP3220 blade server is installed. This
fan tray upgrade is required to provide adequate cooling and preventthe system
from overheating or shutting down due to an over temperature condition that can
occur with the older fan trays.
Toverify if the fan tray upgrade is installed on a Sun Netra CT 900 server, log
into the Shelf Manager and issue the following command for fan trays 1,2, and
3:
If "Product Part / Model Number = 371-3033-xx", an upgraded fan tray is
installed. If "Product Part / Model Number" is not 371-3033, an old fan tray is
installed and the upgrade is required. Refer to the Sun Netra CT 900 Server
Upgrade Guide (820-3255) for more information.
2.2.2.2 Installing Optional Components
Use the following table to locate your options and installation instructions.
# clia fruinfo fan_tray 1 | grep "Product Part"
DIMMs Section2.3.6.1, “DIMM Requirements” on page 2-19
Section2.3.6.2, “Installing a DDR2 DIMM” on page 2-21
Compact Flash card Section2.3.7, “Installing the Optional Compact Flash Card” on
page2-24
AMC card Section2.3.8, “Installing Optional AMC Cards” on page 2-26