FIGURE 2-5Installing a DIMM

6.Press the top edge of the DIMM toward the blade server until the retainer clips click into place in the notches on the DIMM sides (FIGURE 2-5).

The small metal retainer clips on each side of the DIMM slot are spring-loaded, and they should click into place in the notches on the sides of the DIMM.

2.3.6.3Removing a DDR2 DIMM

If you are returning the DIMM or the blade server for service, or if you are replacing a DIMM with another DIMM, remove the DIMM from the Sun Netra CP3220 blade server.

Note – Safely store the original factory-shipped DIMM and related DIMM packaging. Store any removed DIMM in the new DIMM packaging.

To remove a DIMM from the Sun Netra CP3220 blade server, perform the following steps:

1. Access the blade server by performing one of the following procedures:

If the Sun Netra CP3220 blade server is installed in an ATCA shelf, remove the blade server from the shelf as explained in Section 2.3.3, “Removing the Sun Netra CP3220 Blade Server” on page 2-18.

Remove the Sun Netra CP3220 blade server from its antistatic envelope and place it on an ESD mat near the ATCA shelf.

2-22Sun Netra CP3220 Blade Server User’s Guide • January 2010

Page 56
Image 56
Sun Microsystems CP3220 manual Removing a DDR2 Dimm, 5Installing a Dimm