A.2.2 PICMG Board Cooling Requirements

TABLE A-1provides the blade server board cooling requirements. No alarms are triggered at any of the listed temperatures for the given airflow.

TABLE A-1Airflow Requirements

Watts

 

 

m3/min

 

 

 

CFM

 

 

Power Level

25˚C

28˚C

 

40˚C

55˚C

25˚C

28˚C

 

40˚C

55˚C

 

140

0.045

0.045

 

0.91

0.91

16

16

 

32

32

 

 

 

 

205

0.045

0.045

 

0.91

0.91

16

16

 

32

32

 

210

0.045

0.045

 

0.91

0.91

16

16

 

32

32

 

 

 

 

 

 

 

 

 

 

 

 

 

A.2.3 PICMG ARTM Cooling Requirements

TABLE A-2provides the Pressure Drop vs. Flow Rate for the ARTM.

TABLE A-2ARTM Pressure Drop

Volumetric

Volumetric

Pressure Drop

Pressure Drop

Pressure Drop

Pressure Drop

Flow Rate

Flow Rate

2 DIMMs (Pa)

2 DIMMs

 

 

8 DIMMs (Pa)

8 DIMMs

 

 

(CFM)

(m3/min)

 

(inches of H

2

O)

 

(inches of H

2

O)

 

 

 

 

 

 

 

 

0

0

0

0

 

 

0

0

 

 

17

0.48

11.16

0.05

 

 

11.16

0.05

 

 

24

0.68

18.61

0.08

 

 

18.61

0.08

 

 

30

0.85

28.53

0.12

 

 

31.01

0.13

 

 

34

0.96

34.73

0.14

 

 

38.45

0.16

 

 

42

1.19

48.38

0.2

 

 

54.58

0.22

 

 

45

1.27

59.05

0.24

 

 

64.5

0.26

 

 

48

1.36

64.5

0.26

 

 

71.95

0.29

 

 

51

1.44

71.95

0.29

 

 

79.39

0.32

 

 

54

1.53

79.39

0.32

 

 

86.83

0.35

 

 

 

 

 

 

 

 

 

 

 

 