For example:
# clia sendcmd 96 2e 81 00 00 2a 01 < | |||
Pigeon Point Shelf Manager Command Line Interpreter | |||
Completion code: 0x0 | (0) | successful completion code | |
Response data: 00 00 | 2A | no data returned | |
|
|
|
|
3.To boot the blade server from the Shelf Manager, type:
#clia activate board n
Note – Once the blade server is booted, reset the blade server to use the primary BIOS image (page 0).
4.10Perform a Live Firmware Upgrade
To upgrade the BIOS firmware while retaining the current BIOS image, follow these steps:
1.Switch the BIOS image from page 0 to page 1.
See Section 4.9, “Use the Secondary BIOS Image” on page
2.Use the Solaris BIOS Update Utility to upgrade the page 1 BIOS image. See Section 4.7, “Updating the BIOS” on page
3.Reboot the system into the updated page 1 BIOS.
See Section 2.3.12, “Resetting the Sun Netra CP3220 Blade Server” on page
Chapter 4 Configuring and Using BIOS Firmware