To reset the jumper and return the CMOS settings to the default settings, perform the following steps:

1.Remove the jumper housing from the run position (P1/P2) and move it to the reset position (P2/P3).

FIGURE 2-11Jumper 1 in the Reset Position

AMC slot B1

Jumper 1

Pin 1

Pin 2

Pin 3

Zone 3

Zone 3

connectors

2.Wait at least one second for the CMOS settings to reset and then move the jumper housing back to the run position.

3.Reinstall the blade server.

Use the procedure in Section 2.2.3.2, “Installing the Blade Server Into the Shelf” on page 2-12.

Note – The blade server will operate normally only when the jumper housing is in the run position.