▼Setting OOS LED Behavior
Note – You must always perform a read, modify, and write to change any of the bits in the control byte.
●At the clia CLI, enter the Set IPMI Control Bits command.
Command |
| NetFn | Opcode |
|
|
|
|
| |
Set IPMI Control Bits | 0x2E | 0xE9 |
| |
|
|
|
|
|
Data Bytes |
|
|
|
|
|
|
|
|
|
Type | Byte | Data Field |
|
|
|
|
|
|
|
Request Data | 1 | 00 |
|
|
| 2 | 00 |
|
|
| 3 | 2A |
|
|
| 4 | Control byte: |
|
|
|
| Bit 0 = LED 2 (Green LED) control bit. |
|
• 1 = IPMC controls green LED.
• 0 = IPMC does not control green LED.
Bit 1 = OOS LED1 (Amber/Red LED) control bit.
•1 = IPMC controls LED1 for default behavior.
•0 = IPMC does not control LED1.
Bits 2 to 7= reserved for future use
Response Data | 1 | Completion Code: |
•[00] OK
•[C1] Command not supported
•[CC] Invalid data in request
(Refer to IPMI specification for more completion codes)