Exmark TT23KCC, TT23KAC, TT20KCC manual Danger, Potential Hazard

Models: TT20KCC TT23KCC TT23KAC

1 44
Download 44 pages 21.62 Kb
Page 16
Image 16
Manual background

3.2.1Remove battery cover from machine. Disconnect the battery cables (negative (black) cable first) and remove battery.

DANGER

POTENTIAL HAZARD

Charging the battery may produce explosive gasses

WHAT CAN HAPPEN

Battery gasses can explode causing serious injury.

HOW TO AVOID THE HAZARD

Keep sparks, flames, or cigarettes away from battery.

Ventilate when charging or using battery in an enclosed space.

Make sure venting path of battery is always open once battery is filled with acid.

3.2.2Check the voltage of the battery with a digital voltmeter. Locate the voltage reading of the battery in the table below and charge the battery for the recommended time interval to bring the charge up to a full charge of 12.6 volts or greater.

IMPORTANT: Make sure the negative battery cables are disconnected and the battery charger used for charging the battery has an output of 16 volts and 7 amps or less to avoid damaging the battery (see chart below for recommended charger settings).

Voltage

Percent

Maximum

 

Charging Interval

Reading

Charge

Charger Settings

 

 

 

12.6 or greater

100%

16 volts/7 amps

No Charging Required

12.4 – 12.6

75

– 100%

16 volts/7 amps

30 Minutes

12.2 – 12.4

50

– 75%

16 volts/7 amps

1

Hour

12.0 – 12.2

25

– 50%

14.4 volts/4 amps

2

Hours

11.7 – 12.0

0 – 25%

14.4 volts/4 amps

3

Hours

11.7 or less

0%

14.4 volts/2 amps

6

Hours or More

Manual background CAUTION

POTENTIAL HAZARD

If the ignition is in the “ON” position there is potential for sparks and engagement of components.

WHAT CAN HAPPEN

Sparks could cause an explosion or moving parts could accidentally engage causing personal injury.

HOW TO AVOID THE HAZARD

Be sure ignition switch is in the “OFF” position before charging the battery.

3.2.3Connect the negative battery cables.

NOTE: If the positive cable is also disconnected, connect the positive (red) cable first, then the negative (black) cable and green/white wire (green/white wire is only on some units). Slip insulator boot over the positive terminal.

NOTE: If time does not permit charging the battery, or if charging equipment is not available, connect the negative battery cables and run the vehicle continuously for 20 to 30 minutes to sufficiently charge the battery.

PART NO. 1-513747

LOCATION: Battery Cover

- 11 -

Page 16
Image 16
Exmark TT23KCC, TT23KAC, TT20KCC manual Danger, Potential Hazard