EDID

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: In the commands below, the EDID data can come from either an active output or be set to a specified value.

 

 

Assign EDID data to an input

 

EAX!*X#EDID}

EdidAX!*X#]

X! = Input number

 

 

 

 

Assign EDID data to all inputs

EA*X#*EDID}

EdidA0*X#]

 

 

 

 

 

 

 

 

Save output #1 EDID data to a

ES*X#EDID}

EdidSX#]

 

 

 

 

 

 

 

 

 

user-defined space

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

View EDID data assignment

 

EA*X!EDID}

X#]

 

X! = Input number

 

 

 

 

X# (EDID) values:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X# value for DMS model

 

Source

X# value for DMS model

 

Source

X# value for DMS model

Source

 

 

1600

2000

3200

3600

 

 

 

1600

2000

 

3200

 

3600

 

 

1600

2000

3200

3600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01

01

01

01

 

Output 1

13

13

 

13

 

13

 

Output 13

N/A

N/A

25

25

Output 25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02

02

02

02

 

Output 2

14

14

 

14

 

14

 

Output 14

N/A

N/A

26

26

Output 26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

03

03

03

03

 

Output 3

15

15

 

15

 

15

 

Output 15

N/A

N/A

27

27

Output 27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

04

04

04

04

 

Output 4

16

16

 

16

 

16

 

Output 16

N/A

N/A

28

28

Output 28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

05

05

05

05

 

Output 5

N/A

17

 

17

 

17

 

Output 17

N/A

N/A

29

29

Output 29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

06

06

06

06

 

Output 6

N/A

18

 

18

 

18

 

Output 18

N/A

N/A

30

30

Output 30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07

07

07

07

 

Output 7

N/A

19

 

19

 

19

 

Output 19

N/A

N/A

31

31

Output 31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

08

08

08

08

 

Output 8

N/A

20

 

20

 

20

 

Output 20

N/A

N/A

32

32

Output 32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

09

09

09

09

 

Output 9

N/A

N/A

 

21

 

21

 

Output 21

N/A

N/A

N/A

33

Output 33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

10

10

10

 

Output 10

N/A

N/A

 

22

 

22

 

Output 22

N/A

N/A

N/A

34

Output 34

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

11

11

11

 

Output 11

N/A

N/A

 

23

 

23

 

Output 23

N/A

N/A

N/A

35

Output 35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

12

12

12

 

Output 12

N/A

N/A

 

24

 

24

 

Output 24

N/A

N/A

N/A

36

Output 36

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 17

 

Command

 

 

ASCII Command

Response

 

Additional Description

 

 

 

 

 

(Host to Unit)

 

(Unit to Host)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X# (EDID) values (continued):

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X# value for DMS model

Resolution

X# value for DMS model

Resolution

 

 

1600

2000

3200

3600

 

 

1600

2000

3200

3600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

21

33

37

640x480 @ 60 Hz

32

36

48

52

1365x768 @ 75 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

22

34

38

640x480 @ 75 Hz

33

37

49

53

1366x768 @ 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

23

35

39

800x600 @ 60 Hz

34

38

50

54

1366x768 @ 75 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

24

36

40

800x600 @ 75 Hz

35

39

51

55

1400x1050 @ 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

25

37

41

852x480 @ 60 Hz

36

40

52

56

1600x1200 @ 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

26

38

42

852x480 @ 75 Hz

37

41

53

57

1920x1200 @ 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23*

27*

39*

43*

1024x768

@ 60 Hz

38

42

54

58

480p @ 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

28

40

44

1024x768

@ 75 Hz

39

43

55

59

576p @ 50 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

29

41

45

1024x852

@ 60 Hz

40

44

56

60

720p @ 50 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26

30

42

46

1024x852

@ 75 Hz

41

45

57

61

720p @ 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27

31

43

47

1280x768

@ 60 Hz

42

46

58

62

1080p @ 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

32

44

48

1280x768

@ 75 Hz

43

47

59

63

1080i @ 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29

33

45

49

1280x1024 @ 60 Hz

44

48

60

64

1080p @ 50 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

34

46

50

1280x1024 @ 75 Hz

45

49

61

65

1080p @ 60 Hz, stereo

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

31

35

47

51

1365x768

@ 60 Hz

4653

5057

6269

6673

User defined

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*= Default setting

Page 13