Installation and Operation, cont’d
DVI Connector Pin Assignments
Figure
| 1 | 8 | 8 | 1 |
|
|
| ||
9 | 17 | 24 | 24 | 17 |
| ||||
| Female Connector | |||
| Male Connector |
DVI signals run at a very high frequency and are especially prone to bad video connections, too many adapters, or excessive cable length. To avoid the loss of an image or jitter, follow these guidelines:
•Do not exceed 16.4 feet (5 meters) on the input or buffered
•Use only the cable designed for DVI signals supplied by Extron.
•Limit or avoid the use of adapters.
•Use only approved DVI connectors.
CUse only cables specifically intended for DVI interfaces. Use of
NThe missing connectors on the included DVI cable are not required for the single link of
Pin | Signal | Pin | Signal | Pin | Signal | |
|
|
|
|
|
| |
1 | TMDS Data 2- | 9 | TMDS Data 1- | 17 | TMDS Data 0- | |
|
|
|
|
|
| |
2 | TMDS Data 2+ | 10 | TMDS Data 1+ | 18 | TMDS Data 0+ | |
|
|
|
|
|
| |
3 | TMDS Data 2/4 | 11 | TMDS Data 1/3 | 19 | TMDS Data 0/5 | |
Shield | Shield | Shield | ||||
|
|
| ||||
|
|
|
|
|
| |
4 | TMDS Data 4- | 12 | TMDS Data 3- | 20 | TMDS Data 5- | |
|
|
|
|
|
| |
5 | TMDS Data 4+ | 13 | TMDS Data 3+ | 21 | TMDS Data 5+ | |
|
|
|
|
|
| |
6 | DDC Clock | 14 | +5 V Power | 22 | TMDS Clock | |
Shield | ||||||
|
|
|
|
| ||
|
|
|
|
|
| |
7 | DDC Data | 15 | Ground (+5 V) | 23 | TMDS Clock | |
|
|
|
|
|
| |
8 | No Connection | 16 | Hot Plug Detect | 24 | TMDS Clock | |
|
|
|
|
|
|
AAppendix A
Reference Information
Specifications
Part Numbers