Refer also to the CrossPoint 450 Plus / MAV Plus User’s Manual at www.extron.com.
Refer also to the CrossPoint 450 Plus / MAV Plus User’s Manual at www.extron.com.
4-6 CrossPoint / MAV Matrix Switchers • Remote Control
CrossPoint / MAV Matrix Switchers • Remote Control 4-7
Command | ASCII command | Response | Additional description |
| (host to switcher) | (switcher to host) |
|
|
|
|
|
Audio output volume |
|
|
|
Set the audio volume to a specific | X@*X%V | OutX@•VolX%] |
|
value |
|
|
|
Example: | 1*50v | Out01•Vol50] | Set output 1 volume to an X% value of 50, an |
|
|
| attenuation of 14 dB (79% of total volume). |
Increment volume | X@+V | OutX@•VolX%] | Increase volume by 1 step. |
Example: | 1+V | Out01•Vol51] |
|
Decrement volume |
| OutX@•VolX%] | Decrease volume by 1 step. |
Read output volume | X@V | X%] |
|
Save and recall presets |
|
|
|
N• If you try to recall a preset that is not saved, the matrix switcher responds with the error code E11.
•The following characters are invalid in preset names: +
Save current configuration as a | X^, | SprX^] | Command character is a comma. |
global preset |
|
|
|
Example: | 9, | Spr09] | Save current ties as preset 9. |
Recall a global preset | X^. | RprX^] | Command character is a period. |
Example: | 5. | Rpr05] | Recall preset 5, which becomes the current |
|
|
| configuration. |
N X@= Output number | 01 | – (maximum number of outputs for your model) |
X%= Volume | 0 – 64 (1 dB/step except for | |
X^= Preset number | 00 | - 64 (00 = current configuration, for viewing only) |
Command | ASCII command Response | Additional description |
Lock (executive) modes
NSee “Setting the front panel locks (Executive modes)” on page
Lock all front panel functions | 1X | Exe1] | Enable Lock mode 1. |
Lock advanced front panel functions | 2X | Exe2] | Enable Lock mode 2. |
Unlock all front panel functions | 0X | Exe0] | Enable Lock mode 0. |
View lock status | X | X&] |
|
|
|
|
|
N X&= Lock mode |
| 0, 1, or 2 |
|
Remote Control, cont’d