Extron electronic MPS 409 Host-to-MPS Communications, USB Configuration Port, Boot-up messages

Models: MPS 409

1 43
Download 43 pages 42.61 Kb
Page 27
Image 27
USB Configuration Port

USB Configuration Port

Drivers for the MPS 409 USB configuration port are loaded automatically when Dataviewer or Firmware Loader, included on the software disc or available at www.extron.com, are loaded.

Host-to-MPS Communications

The MPS switcher accepts Simple Instruction Set (SIS) commands through the RS‑232 or USB configuration port. SIS commands consist of one or more characters per command field. They do not require special characters to begin or end the command character sequence. Each response to an SIS command ends with a carriage return and a line feed (CR/LF = ]), which signals the end of the response character string. A string is one or more characters.

MPS Switcher-initiated Messages

When a local event occurs, such as a front panel operation, the MPS switcher responds by sending a message to the host. The MPS 409-initiated messages are listed below (underlined).

Boot-up messages

(c) Copyright 2010, Extron Electronics, MPS 409, Vx.xx ]

The copyright message is initiated by the switcher when it is first powered on. Vx.xx is the firmware version number.

Status change messages

The switcher-initiated status change messages are a result of front panel operations (actual or software-simulated). The status change messages are the same as switcher responses to certain commands. See the last column of the command/response tables on the following pages.

MPS Switcher Error Responses

When the MPS switcher receives an SIS command and determines that it is valid, it performs the command and sends a response to the host device. If the switcher is unable to perform the command because the command is invalid or contains invalid parameters, it returns an error response to the host. The error response codes are as follows:

E01 ] — Invalid input channel number (too large)

E10 ] — Invalid command

E13 ] — Invalid value (out of range)

MPS 409 • SIS Programming and Control

21

Page 27
Image 27
Extron electronic MPS 409 manual Host-to-MPS Communications, USB Configuration Port, MPS Switcher-initiated Messages