Switcher- initiated messages

Program audio ducking level in talk over mode

 

 

 

Adjust audio ducking level

X1@ * 58#

Adl X1@ ]

Adjusts how much

 

 

 

 

(X1@ = 0 to 30 dB) the program

 

 

 

 

audio ducks (automatically

 

 

 

 

decreases) in talk over mode.

 

 

 

 

0 = ducking off.

 

Increment audio ducking

+*58#

Adl X1@ ]

 

 

Decrement audio ducking

–*58#

Adl X1@ ]

 

 

View audio ducking level

58#

X1@ ]

 

 

 

 

 

 

 

Volume level

 

 

 

 

Specify volume variable

X1) V/v

Vol X1) ]

Volume level is X1).

 

 

 

 

X1) = 000 – 100 (program

X

 

 

 

volume adjustment range).

 

Increment volume

+V

Vol X1) ]

Volume level is X1).

 

Decrement volume

–V

Vol X1) ]

Volume level is X1).

 

View volume

V

X1) ]

Volume level is X1).

 

Audio mute

X# Z/z

Amt X# ]

X#: 0 = off and 1 = on.

X

View audio mute status

Z/z

X# ]

Mute status is (0=off, 1=on).

 

 

 

 

 

 

Mic level

 

 

 

 

Specify gain

16* X$ G

Aud X$ ]

X$ = audio gain in dB = 0 to

 

 

 

 

12. This variable is a positive

X

 

 

 

number.

 

Specify attenuation

16*X% g

Aud X% ]

X% = attenuation in dB = 1 to

 

 

 

 

66. This variable is a positive

 

 

 

 

number.

 

View mic volume

16G/g

X^ ]

X^ = overall mic gain or

 

 

 

 

attenuation between -66 dB

 

 

 

 

and +12 dB. This response

 

 

 

 

variable indicates attenuation as

 

 

 

 

a negative number and gain as

 

 

 

 

a positive number.

 

 

 

 

 

 

Mic mute on/off

 

 

 

 

Turn mic mute on/off

X# M/m

Mix X# ]

Toggles mic mute on or off.

X

 

 

 

X#: 0 = off, 1 = on.

 

 

 

 

View mic mute status

M/m

X# ]

Mic mute status: (0=off, 1=on).

 

 

 

 

 

 

Mic talk-over threshold

 

 

 

 

Display talk-over threshold

X* * 2 #

Thr X* ]

Shows the mic threshold

 

 

 

 

number. X* = 0 through 15,

 

 

 

 

default = 8.

 

Decrement threshold

– * 2#

Thr X* ]

Decrements mic threshold one

 

 

 

 

step.

 

Increment threshold

+ * 2#

Thr X* ]

Increments mic threshold one

 

 

 

 

step.

 

View mic talk threshold

2 #

X* ]

 

 

 

 

 

 

 

MPS 409 • SIS Programming and Control