Installation
Installation Overview
To install and set up the SW USB switcher,
1Mount the switcher on a rack shelf or furniture, if desired.
2Connect host device(s) to one or more SW USB input connectors, using USB cable lengths of up to 15' (4.5 m).
3Connect one or more peripheral USB devices to the
SW USB Output Hub ports, using USB cable lengths of up to 15' (4.5 m).
4If desired, connect an
NYour
5If desired, connect an external Extron A/V switcher to the
6If desired, wire one of the provided
7If using a different power supply from the one that was provided, wire the provided
8(SW4 USB Plus only) If desired, attach a keyboard and/or mouse to output port 3 and/or 4, and set the appropriate DIP switch(es) for host emulation. (See “Host emulation (SW4 USB Plus only),” in chapter 3, “Operation.”
9Power on the USB peripheral devices, if applicable.
10Power on the SW USB switcher.
11Power on the host device(s).
Mounting the SW USB Series Switcher
The SW USB Series switcher can be set on a table, mounted on a rack shelf, or mounted under a desk, podium, or table.
Tabletop use
Four adhesive rubber feet are included with the SW USB switcher. For tabletop use, attach one foot at each corner on the bottom of the unit, and place the switcher in the desired location.
Rack mounting
For optional rack mounting, do not install the rubber feet. Mount the switcher on any of the following rack shelves:
•RSB 123 — 1U, 3.5" Deep VersaTools® Basic Rack Shelf (part
•RSF 123 — 1U, 3.5" Deep VersaTools Rack Shelf Kit (part
•RSB 126 — 1U, 6" Deep Basic Rack Shelf (part
•RSU 126 — 1U, 6" Deep Universal Rack Shelf Kit (part
•RSB 129 — 1U, 9.5" Deep Basic Rack Shelf (part
•RSU 129 — 1U, 9.5" Deep Universal Rack Shelf Kit (part
UL rack mounting guidelines
The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of the equipment in a rack.
1. Elevated operating ambient temperature — If the equipment is installed in a closed or
2. Reduced air flow — Install the equipment in a rack so that the amount of air flow required for safe operation of the equipment is not compromised.
3. Mechanical loading — When mounting the equipment in the rack, ensure that uneven mechanical loading does not cause a hazardous condition.