Problem solving

SIS Configuration and Control, cont’d

10. Click the Upload button. A status bar showing the progress of the upload appears in the Firmware Loader window. The firmware upload to the switcher may take several minutes. Once the status bar has progressed fully from left to right, the Firmware Loader resets the switcher.

In addition, messages appear on the Firmware Loader window, indicating when the unit is uploading the firmware, then resetting itself.

NIf the uploading process is interrupted or the Firmware Loader exits before the upload is complete, the unit is reset to its factory defaults.

11. When the firmware upload process is completed, the message “Transfer Complete!” is displayed, and the new firmware version number appears in the Current Unit Information field.

Click Exit to close the Firmware Loader.

Problem solving

If you inadvertently load an incorrect version of firmware to the SW USB (e.g., version 1.01 instead of 1.02), you can load the desired version, which overwrites the previous one.

If the firmware that you attempt to load is corrupt, the switcher reverts to the most recently loaded version that was functional. To load the new firmware, obtain another copy of the desired version and perform the upload procedure again.

4-10 SW USB Series • SIS Configuration and Control

SW USB Series • SIS Configuration and Control 4-11