XTP T UWP 302 • Installation and Operation 13
Power Connection
Apply power to the transmitter locally with the provided power supply or remotely with a
power injector or an XTP matrix switcher.
ATTENTION: XTP remote power is intended for indoor use only. No part of the network
that uses XTP remote power should be routed outdoors.

Local power

SECTION A–A
AA
Power Supply
Output Cord
2-Pole Captive Screw
Connector
Ridges
Smooth
Tie
Wrap
3/16”
(5 mm) Max.
Figure 14. Power Wiring
The XTP T UWP 302 can be connected to a local power supply.
WARNING: Electric shock hazard. The two power cord wires must be kept separate
while the power supply is plugged in. Remove power before wiring.
ATTENTION:
This product is intended to be supplied by a Listed Power Unit marked “Class 2”
or “LPS,” rated 12 VDC, 1.0 A minimum. Always use a power supply supplied by
or specified by Extron. Use of an unauthorized power supply voids all regulatory
compliance certification and may cause damage to the supply and the end
product.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling
spaces or in wall cavities. The installation must always be in accordance with the
applicable provisions of National Electrical Code ANSI/NFPA 70, article 75 and
the Canadian Electrical Code part 1, section 16. The power supply shall not be
permanently fixed to a building structure or similar structure.
Power supply voltage polarity is critical. Incorrect voltage polarity can damage the
power supply and the unit. The ridges on the side of the cord identify the power
cord negative lead.
The length of the exposed (stripped) copper wires is important. The ideal length is
3/16 inch (5 mm).
TIP: Do not tin the stripped power supply leads. Tinned wires are not as secure in the
captive screw connectors and could be pulled out.
Use the supplied tie wrap to strap the power cord to the extended tail of the connector.