(14/32) - DRO operation - Installation/Operation - 20i-T / 30i-T - V0612

2.5.5.2 Recall and Reset modes

Toggles between the recall and Preset modes.
RECALL mode The recall mode lets enter the current axis position into the calculator.
Enters the current position of the selected axis into the calculator. The [Z] key
for the Z1 axis and the [Zs] key for the Z2 axis.
PRESET mode The preset mode lets preset the desired axis with the result of an operation.
Presets the selected axis with the result of the calculation. The [Z] key for the
Z1 axis and the [Zs] key for the Z2 axis.
Example Calculate [Z1 position] / 5 and preset the Z axis with the result.
Example: calculator
Display keys Operation Display
X = 25
Z = 10
Goes into calculator mode X = 0
Z = 0
Zs = Ad
X = 0
Z = 0
Zs = Ad
Goes into RECALL mode
and enters the current
position in the Z axis.
X = 10
Z = 0
Zs = Ad
X = 10
Z = 0
Zs = Ad
Presets the divisor (5) X = 10
Z = 5
Zs = Ad
X = 10
Z = 0
Zs = Ad
Selects the divide operation X = 10
Z = 5
Zs = di
X = 10
Z = 5
Zs = di
Result in the X display (2) X = 2
Z =
Zs = di
X = 2
Z =
Zs = di
Goes into Preset mode X = 2
Z = Preset
Zs =
X = 2
Z = Preset
Z =
Presets the Z1 axis with the
result of the calculation.
X = 25
Z = 2
Zs = di
X = 25
Z = 2
Zs = di
Quits the calculator mode. X = 25
Z = 2
Zs =
5
3 times