Firex SERIES 10000 specifications Table Of Contents, Series, Danger, Carbon Monoxide Alarm

Models: SERIES 10000

1 8
Download 8 pages 22.28 Kb
Page 1
Image 1
Carbon Monoxide Alarm

©2006 INVENSYS CONTROLS AMERICAS

Carbon Monoxide Alarm110-1125C

110-1125C

SERIES 10000

MODEL COE: 120 V AC/DC CARBON MONOXIDE ALARM WITH BATTERY BACKUP

SERIES 10200

MODEL COE-B: DC ONLY CARBON MONOXIDE ALARM

SERIES 10400

MODEL COEA: 120 V AC CARBON MONOXIDE ALARM

PLEASE READ AND SAVE THIS ENTIRE MANUAL

Installer: Please leave this manual with the product

Electrical rating:

120V AC, 60Hz, 0.05amp

Single or multiple station CO alarm Model COE includes 9V battery back-up

TABLE OF CONTENTS

About This Carbon Monoxide Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Specifications and Important Product Information . . . . . . . . . . . . . . . . . . . . . . . .1 Where to Install This CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 How To Install This CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4

1. Installing an AC With Battery Back-Up Alarm . . . . . . . . . . . . . . . . . . . . . . . .3

2. Interconnecting AC Only and AC/DC Alarms . . . . . . . . . . . . . . . . . . . . . . . .3

If the Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Chart : Understanding the LED Lights and Horn Patterns . . . . . . . . . . . . . . .5 & 6 Troubleshooting the CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 & 6 Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Symptoms of CO Poisoning and sources of CO in the home

Testing and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Service and Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

The following symbols identify the most important safety messages in this manual.

SERIES 10000DANGER

SERIES 10200WARNING

SERIES 10400CAUTION

When you see this symbol, be aware that if the message is ignored, the hazard WILL result in SEVERE bodily injury or death.

When you see this symbol, be aware that if the message is ignored, the hazard CAN cause SEVERE bodily injury or death.

When you see this symbol, be aware that if the message is ignored, the hazard CAN or WILL cause MINOR bodily injury.

About this Carbon Monoxide Alarm:

This CO alarm is designed to detect carbon monoxide gas. It is NOT designed to detect smoke, fire, or any other type of gas. If this CO alarm sounds its alarm horn, DO NOT assume that it is a false alarm. The alarm horn requires your immediate action.

PLEASE READ AND SAVE THIS ENTIRE MANUAL WARNING

Individuals with medical problems may consider using warning devices which provide audible and visual signals for carbon monoxide concentrations under 30ppm.

SPECIFICATIONS AND IMPORTANT

PRODUCT INFORMATION

Product Features

Monthly Self-Test:Approximately every 30 days this alarm performs a silent internal system test to verify sensor operation utilizing True Gas Testing. True Gas Testing verifies that the CO sensor is nearing the end of its service life. Traditional CO alarms test the sensor by simulating an alarm condition electrically. This is the first CO sensor that runs a diagnostic test by generating a very small and harmless amount of hydrogen gas. If the sensor is working properly, it WILL NOT chirp. If the alarm chirps during the monthly self-testing, it is indicating a problem with the unit. Refer to the charts on pages 5 and 6 for the appropriate actions to take should this occur. You must still test the alarm weekly to verify proper horn operation.

Trigger Alarm Locator™ (TAL™): Most interconnect tests trigger all alarm horns simultaneously for the duration of the test. This unique system alternates between a 10 second ALL ON cycle and a 50 second cycle where only the initiating alarm is sounding.

Alarm Controlled Interconnect Test: In an interconnected system, this feature will alarm the local unit first, then quiet the local unit while the remote units alarm.

Smart Quiet™ Low Battery 1: Allows the homeowners to silence the low battery chirp for up to 10 hours, giving them time to go back to sleep and/or purchase a fresh replacement battery.

Smart Quiet™ Low Battery 2: Indicates the battery no longer has enough voltage to adequately protect in the event of a power outage or a battery-only installation. The Smart Quiet™ feature will no longer silence the chirp.

THE BATTERY MUST BE REPLACED IMMEDIATELY.

Required Power Supply (Series 10000 and 10400 only)

This CO alarm requires constant 120-volt, AC power AND/OR a working 9-volt battery to operate properly. This alarm WILL NOT work if AC power is not connected or has failed or been interrupted for any reason AND the battery is removed, drained or improperly connected. DO NOT use any other kind of battery except as specified in this manual.

1