LED AND HORN PATTERNS

LED AND HORN PATTERNS

LIGHTS

GREEN light ON

YELLOW light blinks once per minute

YELLOW light blinks during horn ramp-up.

RED blinks 4 times right after horn sounds.

YELLOW light blinks during horn ramp-up.

RED blinks 4 times right after horn sounds.

YELLOW light flashes 2 times per minute after horn beeps

YELLOW light flashes 3 times per minute after horn beeps

YELLOW light flashes constantly after horn beeps

RED light flashes 4 times right after horn

RED light flashes 3 times every 10 seconds

RED light flashes 1 time every 10 seconds

SMART BUTTON KEY

Quick push activates a local Push-to-Test sequence

Press and RELEASE button before you hear the third chirp. The system will perform a single local test cycle.

Press and HOLD button.

The system will perform a single local test cycle, then repeat the interconnect test until you release the button.

Quick press will eliminate the low-battery warning for about 10 hours

Smart Button WILL NOT silence the low battery chirp! Replace battery immediately!

Press to check the alarm again. Replace alarm if it remains in the fault condition.

Quick press activates CO Reset

Quick press erases the CO latched signal

Quick press activates Smart Quiet™ Trigger Alarm locator for Model COE and COEA alarms.

ING THE CO ALARM

WARNING DO NOT disconnect the battery or AC power to quiet an unwanted alarm. This will remove your protection.

Use Quick Quiet™ False Alarm Control by pushing the Smart Button.

PROBLEM

SOLUTION

 

 

The horn beeps once,

The alarm is operating properly. The Firex patented

then two beeps, then

Horn Ramp-Up feature lets you start the test sequence

three beeps, pauses, and

and move away from the unit before the full alarm

then sounds the full

horn sounds.

alarm when using the

 

Smart Button to test.

 

 

 

Alarm sounds;

Take Emergency Safety Actions in all alarm situations! If

no hazard present.

no hazard proves to be present: Test the alarm to check

 

for proper functioning. Clean the alarm. (See TESTING

 

AND MAINTENANCE.) Check that the alarm is placed

 

properly. (See AGENCY RECOMMENDATIONS FOR

 

ALARM PLACEMENT.)

 

 

The alarm beeps once a

The battery needs to be replaced. Turn off power and

minute and YELLOW

replace the battery. (See “REPLACING THE BATTERY” in

light flashes.

“TESTING AND MAINTENANCE”.) Push the Smart Button

 

to temporarily quiet the low battery signal for 10 hours.

 

 

Horn beeps twice a

Push the Smart Button to allow alarm to reset and self

minute and YELLOW

test. If fault signal continues, alarm is no longer providing

light flashes.

protection and must be replaced.

 

 