LED AND HORN PATTERNS
LIGHTS
GREEN light ON
YELLOW light blinks once per minute
YELLOW light blinks during horn
RED blinks 4 times right after horn sounds.
YELLOW light blinks during horn
RED blinks 4 times right after horn sounds.
YELLOW light flashes 2 times per minute after horn beeps
YELLOW light flashes 3 times per minute after horn beeps
YELLOW light flashes constantly after horn beeps
RED light flashes 4 times right after horn
RED light flashes 3 times every 10 seconds
RED light flashes 1 time every 10 seconds
SMART BUTTON KEY
Quick push activates a local
Press and RELEASE button before you hear the third chirp. The system will perform a single local test cycle.
Press and HOLD button.
The system will perform a single local test cycle, then repeat the interconnect test until you release the button.
Quick press will eliminate the
Smart Button WILL NOT silence the low battery chirp! Replace battery immediately!
Press to check the alarm again. Replace alarm if it remains in the fault condition.
Quick press activates CO Reset
Quick press erases the CO latched signal
Quick press activates Smart Quiet™ Trigger Alarm locator for Model COE and COEA alarms.
ING THE CO ALARM
WARNING DO NOT disconnect the battery or AC power to quiet an unwanted alarm. This will remove your protection.
Use Quick Quiet™ False Alarm Control by pushing the Smart Button.
PROBLEM | SOLUTION |
|
|
The horn beeps once, | The alarm is operating properly. The Firex patented |
then two beeps, then | Horn |
three beeps, pauses, and | and move away from the unit before the full alarm |
then sounds the full | horn sounds. |
alarm when using the |
|
Smart Button to test. |
|
|
|
Alarm sounds; | Take Emergency Safety Actions in all alarm situations! If |
no hazard present. | no hazard proves to be present: Test the alarm to check |
| for proper functioning. Clean the alarm. (See TESTING |
| AND MAINTENANCE.) Check that the alarm is placed |
| properly. (See AGENCY RECOMMENDATIONS FOR |
| ALARM PLACEMENT.) |
|
|
The alarm beeps once a | The battery needs to be replaced. Turn off power and |
minute and YELLOW | replace the battery. (See “REPLACING THE BATTERY” in |
light flashes. | “TESTING AND MAINTENANCE”.) Push the Smart Button |
| to temporarily quiet the low battery signal for 10 hours. |
|
|
Horn beeps twice a | Push the Smart Button to allow alarm to reset and self |
minute and YELLOW | test. If fault signal continues, alarm is no longer providing |
light flashes. | protection and must be replaced. |
|
|
For Technical Support:
PH: (800)
Email: technical service@invensys.com
Website: www.icca.invensys.com/firex
6