Technical Manuals Online! -
SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS
| (ALPHA DISPLAY KEYPADS) | |
S O U N D | C A U S E | D I S P L A Y |
LOUD, INTERRUPTED* | FIRE ALARM | FIRE is displayed; descriptor of zone in alarm is displayed. |
Keypad & External |
|
|
LOUD, CONTINUOUS* | BURGLARY/AUDIBLE | ALARM is displayed; descriptor of zone in alarm is also displayed.. |
Keypad & External | EMERGENCY ALARM | Also see "Exit Alarm Warning Displays and Sounds" on page 21. |
ONE SHORT BEEP | a. SYSTEM DISARM | a. DISARMED/READY TO ARM is displayed. Green READY indicator is lit. |
(not repeated) | b. SYSTEM ARMING ATTEMPT | b. The number and descriptor of the open protection zone is displayed. |
Keypad only | WITH AN OPEN ZONE | Green READY indicator (if present) is not lit. |
| c. BYPASS VERIFY | c. Numbers and descriptors of the bypassed protection zones are displayed (One beep is |
|
| heard for each zone displayed). Subsequently, the following is displayed: DISARMED |
|
| BYPASS Ready to Arm |
ONE SHORT BEEP every | SYSTEM IS IN TEST MODE | Opened Zone identifications will appear. |
40 sec. Keypad only |
|
|
ONE BEEP every 40 sec. | a. LOW BATTERY AT A XMTR | a. LO BAT displayed with description of transmitter. |
Keypad only | b. SYSTEM MAIN BATT. WEAK | b. LO BAT displayed with no transmitter description. |
| ||
| c. TROUBLE | c. CHECK displayed. Descriptor of troubled protection zone is displayed. |
TWO SHORT BEEPS | ARM AWAY OR MAXIMUM | ARMED AWAY or ARMED MAXIMUM is displayed. Red ARMED indicator is lit. |
Keypad only |
|
|
THREE SHORT BEEPS | a. ARM STAY OR INSTANT | a. ARMED STAY or ARMED INSTANT is displayed. Red ARMED indicator is lit. |
Keypad only | b. ZONE OPENED WHILE SYS- | b. CHIME displayed. Pressing ✴/ READY key will display descriptor of opened zone. |
| ||
| TEM IS IN CHIME MODE | c. Open protection zone descriptor is displayed. |
| c. ZONE OPENED WHILE SYS- | |
| TEM IS IN TEST MODE |
|
RAPID BEEPING | MEMORY OF ALARM | FIRE or ALARM is displayed; descriptor of zone in alarm is displayed. |
Keypad only |
|
|
SLOW BEEPING | a. ENTRY DELAY WARNING | a. DISARM SYSTEM OR ALARM WILL OCCUR is displayed. Exceeding the delay time |
Keypad only |
| without disarming causes alarm. |
| b. EXIT DELAY ALERT | b. ARMED AWAY or ARMED MAXIMUM is displayed. Slow beeps change to fast during |
| (if programmed) | last 5 sec of exit delay. |
*If bell is used as external sounder, fire alarm is pulsed ring (see page 29); burglary/audible emergency is steady ring. Note: Also see Other Trouble Displays and Total Power Failure under TROUBLE CONDITIONS on pages 27 and 28.
– 3 4 –