SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS

(FIXED-WORD DISPLAY KEYPADS)

S O U N D

C A U S E

D I S P L A Y

LOUD, INTERRUPTED*

FIRE ALARM

FIRE and ALARM are displayed; protection zone in alarm is displayed.

Keypad & External

 

 

LOUD, CONTINUOUS*

BURGLARY/AUDIBLE

ALARM is displayed; protection zone in alarm is also displayed.

Keypad & External

EMERGENCY ALARM

Also see "Exit Alarm Warning Displays and Sounds" on page 21.

ONE SHORT BEEP

a. SYSTEM DISARM

a. Only READY is displayed. Green READY indicator (if present) is lit.

(not repeated)

b. SYSTEM ARMING ATTEMPT

b. NOT READY is displayed, open protection zone number is displayed.

Keypad only

WITH AN OPEN ZONE

Green READY indicator (if present) is not lit.

 

 

c. BYPASS VERIFY

c. The bypassed protection zone numbers are displayed. (One beep for each number

 

 

displayed.) BYPASS displayed.

ONE SHORT BEEP

SYSTEM IS IN TEST MODE

Opened Zone identifications will appear.

(once every 40 seconds)

 

 

Keypad only

 

 

ONE BEEP every 40 sec.

a. LOW BATTERY AT XMTR

a. BAT displayed with ID number of transmitter.

Keypad only

b. SYST. MAIN BATT. WEAK

b. BAT displayed with no transmitter ID

 

c. TROUBLE

c. CHECK displayed. Troubled protection zone is displayed.

TWO SHORT BEEPS

ARM AWAY OR MAXIMUM

AWAY and (if MAXIMUM) INSTANT are displayed.

Keypad only

 

 

THREE SHORT BEEPS

a. ARM STAY OR INSTANT

a. STAY and (if INSTANT) INSTANT are displayed. Red ARMED indicator is lit.

Keypad only

b. ZONE OPENED WHILE SYS-

b. CHIME displayed. Pressing / READY key will display opened zone.

 

TEM IS IN CHIME MODE

c. Open protection zone number is displayed.

 

c. ZONE OPENED WHILE SYS-

 

TEM IS IN TEST MODE

 

RAPID BEEPING

MEMORY OF ALARM

FIRE and/or ALARM is displayed; zone in alarm is displayed.

Keypad only

 

 

SLOW BEEPING

a. ENTRY DELAY WARNING

a. No display during delay; Exceeding the delay time without disarming causes alarm.

Keypad only

b. EXIT DELAY ALERT

b. AWAY or (if MAXIMUM) AWAY INSTANT is displayed. Slow beeps change to fast during

 

 

(if programmed)

last 5 sec of exit delay.

*If bell is used as external sounder, fire alarm is pulsed ring (see page 29); burglary/audible emergency is steady ring. Note: Also see Other Trouble Displays and Total Power Failure under TROUBLE CONDITIONS on pages 27 and 28.

– 3 5 –

Page 35
Image 35
First Alert FA142C user manual Fixed-Worddisplay Keypads, Summary Of Audible/Visual Notifications