5-9
Specifications and Reference Data

TABLE5-3. 444 Model Structure.

Model Product Description
444 Alphaline Temperature Transmitter
Code Input Type(1)
(1) Refer to TemperatureSensors, Assemblies , and Accessories Produc t DataS heet,Ros emount pub.no. 00813-0100-2654 for information
about Rosemount sensor assemblies.
TemperatureSpan
Minimum Maximum Base Temperature
Minimum Maximum Upper Range Limit
RL1
RL2
RL3
Platinum RTD
100 VR0
linearized output
45 °F (25 °C) 135 °F (75 °C)
125°F (70 °C) 380°F (210°C)
360 °F (200 °C) 1080 °F (600 °C)
–58 °F (–50 °C) 300 °F (150 °C)
–58 °F (–50 °C) 300 °F (150 °C)
–58 °F (–50 °C) 300 °F (150 °C)
435°F (225 °C)
680°F (360 °C)
1380 °F (750 °C)
RL9 SpecialInput, Range or Accuracy (minimum span 3 V)
TJ1
TJ2
TK1
TK2
TK3
TE1
TE2
TT1
TR1
TS1
Thermocouple
Type J
Type J
Type K
Type K
Type K
Type E
Type E
Type T
Type R
Type S
180°F (100 °C) 540 °F (300 °C)
504°F (280 °C) 1458 °F (810 °C)
180°F (100 °C) 540 °F (300 °C)
504°F (280 °C) 1510 °F (840 °C)
845°F (470 °C) 2540 °F (1410 °C)
180°F (100 °C) 540 °F (300 °C)
504°F (280 °C) 1510 °F (840 °C)
180°F (100 °C) 540 °F (300 °C)
1467 °F (815 °C) 3000°F (1670 °C)
1467 °F (815 °C) 3000°F (1670 °C)
–58 °F (–50 °C) 3 00 °F (150 °C)
–58 °F (–50 °C) 9 30 °F (500 °C)
–58 °F (–50 °C) 3 00 °F (150 °C)
–58 °F (–50 °C) 9 30 °F (500 °C)
–58 °F (–50 °C) 9 30 °F (500 °C)
–58 °F (–50 °C) 3 00 °F (150 °C)
–58 °F (–50 °C) 9 30 °F (500 °C)
–58 °F (–50 °C) 3 00 °F (150 °C)
0° F (–18 °C) 1500 °F (815 °C)
0° F (–18 °C) 1500 °F (815 °C)
840 °F (450 °C)
1400 °F (760 °C)
840 °F (450 °C)
2440 °F (1340 °C)
2500 °F (1370 °C)
840 °F (450 °C)
1830 °F (1000 °C)
750 °F (400 °C)
3200 °F (1760 °C)
3200 °F (1760 ��C)
T_9 SpecialRange or Accuracy (minimum span 3 mV, maximum span 100 mV)
MV1
MV2 Millivolt
Millivolt 5mV 15mV
15mV 45 mV –2mV 8 mV
–2mV 20mV 23mV
65 mV
MV9 Special Range or Accuracy (m inimum span 3 mV,maximum span 100 mV)
Code Lossof Input Indication
U
D
N
Upscale (standard for all input types)
Downscale
None (not available for platinum RTD inputs)
Code Calibration
1
2
3
Trimto IEC 751 Class B (RTD) or NIST Curve (thermocouple)
Trimto Specific Model 68/78/88 Cal ibration Schedule
Trimto Other Nominal Curve (customer must specify separately) (Note : Millivoltinpu t must use Code 3.)
Code Meter Options
A
B
C
D
E
None
Integral Analog Meter, Special Scale (same as calibrated range)
Integral Analog Meter, 0–100% Scale
Integral LCD Meter, 0–100% Scale(2)
Integral LCD Meter, Special Scale (specify range, mode, and engineering units )(1)

(2) LCD Meters are only availablewith RL1, RL2, or RL3. (may be reconfigured in the field.)

Code MountingBracket
1
2None
Mounting Bracket for 2-inch Pipe or Surface Mounting
Code HazardousArea Certifications
NA
E5
I5
E6
I6
E7
I7
N7
E8
I8
N1
NoCer tification Required
FMExplosion-Proof Approval
FM Intrinsic Safety and Non-incendive Approval
CSAExplosion-Proof Approval
CSA Intrinsic Safety Approval (444RL and 444T only)
SAAExplosion-Proof Cer tification
SAAIntr insic SafetyCer tification
SAA Non-incendive Certification
CESI Explosion-Proof Certification (When ordering a transmitter wi th this option, place a W before the model number: W444.)
CESI Intrinsic Safety Certification (When ordering a transmitter with this option, place a W before the model number : W444.)
BASEEFANon-incendive Certification (When ordering a transmitter with this option, place a T before the modelnumber : T444.)
Code Options
Q4
A1
A2
2-PointCalibration Certificate
One (1) ½ NPT to M20 (CM 20) SST Thread Adapter
One (1) ½ NPT to M20 (CM 20) SST Thread Adapter
Code Special
RXXXX U nique Range (use with RL9, T_9, and MV9 inputs)
TypicalModel Number: 0444 RL3 U 1 A 2 E5 Q4