Check the Water Softener:

If fitted, check the water softener coils, these can be checked at harness P202

Remove the water softener harness from the controller, and using a multimeter check the resistance between pins 1 & 2 for the softener bypass coil - take care not to spread the pins with the meter probes.

The following resistances should apply: 65 Ohms (+/- 10 Ohms)

Check the resistance between pin 3 & 4 for the brine pump,

The following resistances should apply: 65 Ohms (+/- 10 Ohms)

If shorted replace the coil, but continue to check the other components.

Or, the coils can be checked with a multimeter at the water softener itself.