3
Check the lid actuators:
These are checked at the chassis harness (P205) between pins 6 & 7, 8 & 9. Normal resistance range may vary, so only replace if open or short circuit.
4
Check the Detergent Dispenser and Rinse Aid Coils:
These can be checked on harness P204
Remove the dispenser harness from the controller, and using a multimeter check the resistance between pins 1 & 2 for the rinse aid pump coil - take care not to spread the pins with the meter probes.
The following resistances should apply: 65 Ohms (+/- 10 Ohms)
9