5DIAGNOSTICS

5.1DishDrawer Diagnostics

DishDrawer™ diagnostics can only be entered in Power Off mode, i.e. when there is no display on the LCD, or the badge LEDs are off.

Note: If the product has been powered off at the wall due to a fault code error, once power is turned back on, wait 20 seconds before trying to enter diagnostics, as the product will be doing a self check in this time, and will not allow diagnostics to be entered.

Diagnostics is entered by holding the KEYLOCK and START/PAUSE buttons simultaneously for 5 seconds. Ensure that KEYLOCK is pushed first

There are currently four levels of diagnostics. To move to the next level press POWER. To enter a level, press START/PAUSE. Once a level has been entered, pressing POWER will exit diagnostics completely. If no level is entered, then the display will cycle through the four levels and exit after the last. On entering diagnostics mode, the first level is the display mode.

5.1.1Display Mode – Level One

In this mode all LEDs and LCD segments (except keylock) are illuminated in the display.

.

Pre Finished

Integrated and Flat Door Models

The following LED’s will show on the secondary display panel

The last two faults are displayed on the LCD for pre finished models.

For integrated or flat door models the secondary control panel LED will show a sequence of lights to show the fault code.

The current fault code is displayed first followed by the previous fault code. E.g.

Pre Finished

Integrated and Flat Door Models

F9 fault code

16

Page 16
Image 16