Fisher & Paykel CG604 Table for the choice of the injectors, Installation instructions

Models: CG604

1 32
Download 32 pages 10.69 Kb
Page 12
Image 12
Do not use any naked flame to check for leaks.

10

Installation instructions

1After connecting the gas supply, check the piping and connections for leaks using a soap and water solution. The presence of bubbles indicates a leak, tighten or replace connections as appropriate.

Important!

Do not use any naked flame to check for leaks.

2The operation of the appliance MUST be tested before leaving.

3Adjust the test point pressure or supply pressure to the value which is appropriate for the gas type.

4Turn on the appliance gas controls and light each burner. Check for a well defined blue flame without any yellow tipping. If any abnormality is evident then check that the burner cap is located properly and the injector nipple is aligned correctly.

5Check the minimum burner setting by quickly rotating the gas control knob from the maximum to the minimum position, the flame must not go out. If adjustment is required carry out the “minimum burner setting adjustment” section following.

6If satisfactory performance cannot be obtained, the installer shall check the installation and notify the local gas supply authority for a gas supply problem, or if it is an appliance problem, our Customer Service Centre should be called to obtain the nearest authorized Service Agent.

7Where the appliance data plate cannot be easily read with the appliance in the installed position the duplicate data plate must be attached to adjacent surface and the duplicate Universal LPG conversion label should also be included where a Universal LPG conversion has been completed.

Table for the choice of the injectors

 

Natural Gas

Universal LPG

Test point Pressure [kPa]

 

1.0

 

2.75

 

 

 

 

 

 

 

 

Injector

 

Gas

Injector

 

Gas

BURNER

Orifice Dia.

 

Consumption

Orifice Dia.

 

Consumption

 

 

 

 

 

 

 

[mm]

 

[MJ/h]

[mm]

 

[MJ/h]

 

 

 

 

 

 

 

Auxiliary

0.85

 

3.60

0.53

 

3.60

 

 

 

 

 

 

 

Semi-rapid

1.12

 

6.30

0.70

 

6.30

 

 

 

 

 

 

 

Rapid

1.45

 

10.30

0.91

 

10.80

 

 

 

 

 

 

 

Wok

1.65

 

13.00

0.95

 

11.90

 

 

 

 

 

 

 

Page 12
Image 12
Fisher & Paykel CG604 installation instructions Table for the choice of the injectors, Installation instructions