11

Conversion procedure (to convert to Universal LPG) replacing the injectors.

Important!

The conversion procedure must be carried out only by an authorised person.

This appliance is suitable for use with Natural gas or Universal LPG (check the “gas type” sticker attached to the appliance). See the “Table for the choice of injectors” for the nominal gas con- sumption and injector size details.

To replace the injectors proceed as follows:

Remove pan supports and burners from the cooktop.

Using a spanner, remove the injector J (figs. 7, 8) and replace it with one according to the gas type (see “Table for the choice of injectors”).

Affix to the appliance the warning label stating that the cooktop has been converted for use with Universal LPG (supplied with the Universal LPG conversion kit.).

A second Universal LPG conversion label should also be affixed to an adjacent surface along with the duplicate data plate.

Important!

If the cooktop is suitable for use with Natural gas and must be converted for use with Universal LPG, before connecting to gas main remove the appliance gas regulator and replace with test point adaptor (see fig. 5, 6)

If the cooktop is suitable for use with Universal LPG and must be converted for use with Natural gas, before connecting to the gas main remove the appliance test point adaptor and replace with gas regulator (see figs. 5, 6).

Note: Gas regulator and test point adaptor are supplied with the appliance (packed with conversion kit)

The burners are designed so that regulation of primary air is not required.

J