F.Combination Horizontal Venting System –SCG-3 Through SCG-6 ONLY – See Figures 10 and 11.

NOTICE

1. Do not exceed maximum vent/air intake lengths.

Refer to Table 4.

This vent system requires components not supplied with the boiler.

2.Install Combination Vent/Air Terminal. See Figure 11.

a. After determining the location with reference to Section B - General Venting Guidelines, cut a 6-1/8 inch square opening in the wall for the air box sub-assembly which is 6 inch square.

b.Remove and save shipping screw from end panel with collar and vent pipe assembly. This will be reinstalled in a later step.

 

Vent Carton Part Number

61106012 (Includes Items Below)

 

 

 

 

 

Description

 

Component Part Number

 

 

 

 

A

Air Box Sub-Assembly (6” square x 2’ long)

 

61106011

 

 

 

 

B

Exterior Wall Cover (10” square)

 

71106016

 

 

 

 

C

4” x 3” Vent Pipe Reducer

 

8116239

 

 

 

 

D

Plate-Seal Exterior Cover (2)

 

71106017

 

 

 

 

E

#8 x ½” Stainless Steel Sheet Metal Screw (19)

 

80860047

 

 

 

 

F

#10 - 32 x ¼” Stainless Steel Machine Screw (8)

 

80860842

 

 

 

 

G

#10 - 32 x ½” Aluminum Spacer (4)

 

80861617

 

 

 

 

COMBINATION HORIZONTAL VENT SYSTEM COMPONENTS