![](/images/new-backgrounds/1076595/7659561x1.webp)
U2
The tub drawer has been sensed as open during the cycle or the exhaust valve is open circuit.
Is the drawer open?
Yes | No |
Check the
Shut the drawer.microswitch is working in diagnostics.
|
| OK |
| Not OK |
|
|
|
|
| ||
|
|
|
|
|
|
| Check the |
|
|
| |
|
|
|
| ||
| mechanical |
| Replace the | ||
| operation of the |
| |||
|
| microswitch. | |||
| the slides. |
| |||
|
|
|
| ||
OK |
| Not OK |
|
|
|
|
|
|
| ||
|
|
|
| ||
|
|
|
|
|
|
Test the exhaust
valve for an openAdjust the slides. circuit.
Note: Tub home microswitch is located on the rear of the left slide runner and is connected in series with the exhaust valve.