Performance Data Sheet For Fisher & Paykel Filter System Model: 836860
®
Replacement Cartridge: 836848
This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI 42 & 53.
System tested and certified by NSF International against NSF/ANSI Standard 53 for the reduction of Asbestos, Atrazine, Benzene, Cyst, | Note that while the testing was performed |
Carbofuran, Lead, Lindane, Mercury, | under standard laboratory conditions, actual |
Chlorine Taste and Odor and Nominal Particulate Class I. | performance may vary. |
|
|
To a capacity of 2,838 liters (750 gallons)
Standard 53: Health Effects
Substance | USEPA MCL | Influent Challenge concentration | Influent |
| Effluent |
| % Reduction | Min. Required | |||||
|
| (mg/L) | Average | Average | Maximum | Average | Maximum | Reduction | |||||
|
|
|
|
|
|
|
|
| |||||
Turbidity | 1 NTU** | 11±1 NTU** | 10.7 NTU** | 0.31 NTU** | 0.49 NTU** | 97.09% | 95.20% | 0.5 NTU** | |||||
Cysts | 99.95% reduction | Minimum 50,000 #L | 166500 #L | <1 | #L | <1 | #L | <99.99% | <99.99% | >99.95% | |||
Asbestos | 99% reduction | 10 7 to 10 8 fibers/L; | 155 MF/L | <1 | MF/L | <1 | MF/L | <99.99% | <99.99% | >99% | |||
fibers greater than 10 um in length | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||
Lead @ pH 6.5 | 0.015 mg/L | 0.15mg/L +10% | 0.153 | mg/L | <0.001 mg/L | <0.001 mg/L | 99.35% | 99.29% | 0.010 | mg/L | |||
Lead @ pH 8.5 | 0.015 mg/L | 0.15mg/L +10% | 0.150 | mg/L | <0.001 mg/L | <0.001 mg/L | 99.33% | 99.29% | 0.010 | mg/L | |||
Mercury @ pH 6.5 | 0.002 mg/L | 0.006mg/L ±10% | 0.006 | mg/L | 0.0003 mg/L | 0.0005 mg/L | 95.70% | 90.91% | 0.002 | mg/L | |||
Mercury @ pH 8.5 | 0.002 mg/L | 0.006mg/L ±10% | 0.006 | mg/L | 0.0008 mg/L | 0.0015 mg/L | 86.22% | 75.31% | 0.002 | mg/L | |||
Atrazine | 0.003 mg/L | 0.009mg/L ±10% | 0.009 | mg/L | <0.002 mg/L | <0.002 mg/L | 76.99% | 75.31% | 0.003 | mg/L | |||
Benzene | 0.005 mg/L | 0.015mg/L ±10% | 0.014 | mg/L | 0.0006 mg/L | 0.0011 mg/L | 95.71% | 92.14% | 0.005 | mg/L | |||
Carbofuran | 0.04 mg/L | 0.08mg/L ±10% | 0.081 | mg/L | <0.001 mg/L | <0.001 mg/L | 98.74% | 98.46% | 0.04 mg/L | ||||
0.075 mg/L | 0.225mg/L ±10% | 0.208 | mg/L | <0.0005 mg/L | <0.0005 mg/L | 99.76% | 99.74% | 0.075 | mg/L | ||||
Lindane | 0.0002 mg/L | 0.002mg/L +10% | 0.002 | mg/L | 0.000025 mg/L | 0.00007 mg/L | 98.72% | 96.50% | 0.0002 mg/L | ||||
Toxaphene | 0.003 mg/L | 0.015±10% | 0.015 | mg/L | <0.001 mg/L | <0.001 mg/L | 92.97% | 91.67% | 0.003 | mg/L | |||
|
| Standard 42: | Aesthetic Effects |
|
|
|
|
|
|
|
| ||
Substance | USEPA MCL | Influent Challenge concentration | Effluent |
| Effluent |
| % Reduction | Min. Required | |||||
|
| (mg/L) | Average | Average | Maximum | Average | Maximum | Reduction | |||||
|
|
|
|
|
|
|
|
|
| ||||
Chlorine Taste & Odor | ~ | 2.0mg/L +10% | 1.88 mg/L | 0.051366364 mg/L | 0.06 | mg/L | 97.26% | 96.84% | >50% | ||||
Nominal Particulate* | ~ | at least10,000 particales/mL | 5,700,000 #/ml | 30,583 | #/ml | 69,000 | #/ml | 99.95% | 98.94% | >85% |
*Measurement in Particles/ml. Particles used were 0.5 - 1 microns. **NTU = Nephelometric Turbidity Units
IMPORTANT: Change the filter cartridge at least every 6 months.
Operation Specifications
Water pressure | |
Water temperature | |
Service flow | 2.9 lpm (.78 gpm) |
Filter capacity | 2,838 liters (750gallons) |
Systems must be installed and operated in accordance with manufacturer's recommended procedures and guidelines. Follow any and all local plumbing codes and requirements. Some local codes may require the use of a licensed plumber or a certified installer when disrupting a potable water line.
Important: Failure to follow instructions may result in voidance of warranty.
Important: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on disinfected water may contain filterable cysts.
EPA Establishment Number
Install on cold water line only.
CAUTION: To reduce the risks associated with water leakage, which, if not
avoided, may result in property damage - check with your plumbing professional
to verify that water pressure is less than 827 kPa (120 psi).
For estimated cost of replacement element, please call