Care and cleaning

Care and cleaning

Important!

9

Always disconnect the appliance from the mains electricity supply before carrying out any servicing or maintenance. Failure to do so may result in death or electrical shock.

Do not let grease deposits accumulate on your VentSurface, as these could create a fire hazard. Do not use harsh/abrasive cleaners, scourers or sharp metal scrapers to clean your VentSurface. Do not clean the areas behind the filters.

How do I know when the filters need cleaning/replacing?

Your VentSurface is set up to alert you when you need

 

 

to clean the aluminium mesh filter (after 30 hours of

2

operation) or replace the carbon filter (after 120 hours

 

 

 

 

 

 

of operation).

 

 

 

 

 

 

 

 

If the aluminium mesh filter needs cleaning, the letter

 

 

 

 

A” will start flashing in the display alternately with the

 

 

 

 

 

 

 

fan speed setting. See the instructions following.

 

 

If you are using an odour-absorbing carbon filter and it

 

 

needs replacing, the letter “C” will start flashing in the

 

 

display alternately with the fan speed setting. See the

 

 

instructions on the following page.

 

 

To clean the aluminium mesh filter

 

 

1

Fig.2 Removing the aluminium mesh filter

1Stop/reset the cleaning alert signal.

If “A” is flashing in the display alternately with the fan speed setting, turn the VentSurface off by pressing the To clean the aluminium mesh filter button, then press the Manual background and Manual background buttons simultaneously and hold down for five seconds until you hear a beep. “8” will show in the display until the alert

signal has been reset.

2Unplug the VentSurface from the power outlet or switch off at the wall.

3Unclick the magnetic stainless steel cover plate and gently lower it down (Fig.2).

4To remove the aluminium mesh filter, pull gently on the release handle with one hand and support the filter from underneath with the other (to prevent it falling onto the cooking surface).

5Wash the aluminium mesh filter by hand using a mild detergent, or in the dishwasher using a short, 60 oC cycle.

6When dry, replace the aluminium mesh filter.

7 Click the protective cover plate back into place.

8 Plug the VentSurface back into the power outlet or switch on at the wall.