ELECTRICAL REQUIREMENTS

PAGE 6 OF 8

The electrical voltage and frequency that is correct for this oven is stated on the serial number plate located inside the top vent. It is the customer responsibility to ensure that this oven is connected to the correct electrical supply.

WARNING : The oven must be connected to a permanent and grounded supply.

Maximum current draw and Maximum Load:

 

240V

220V

Double :

38.2 A 9.2 kW

35 A 7.7 kW

Single :

21 A 5.1 kW

19.5 A 4.3 kW

WIRING REQUIREMENTS

A circuit breaker appropriate for the product is recommended.

The electrical supply conduit must be securely clamped in the cable clamp located inside the product.

Do ensure a suitable disconnection switch is incorporated in the permanent wiring, positioned to comply with the local wiring rules and regulations. A means of disconnection with at least a 3mm air gap contact separation in all poles must be incorporated into the fixed wiring in accordance with the wiring rules, unless the local wiring rules allow for the following variation. A means of disconnection from the supply having an air gap separation in all active (phase) conductors must be incorporated in to the fixed wiring.

WIRING INSTRUCTIONS

1.Remove the top panel from the product.

2.Feed the oven electrical supply cable through the grommeted hole on the

45o corner at the rear of the product. Then thread that cable through the burst hole and the wiring clamp.

3.Connect the electrical supply cable to the earth post and mains terminal block as indicated on the diagram below.

It is recommended to use an appropriate terminal lug to connect the cable to the mains terminal block and earth post.

4. Secure the wiring clamp and re-fit the top panel.

wiring clamp

Page 6
Image 6