Electrical requirements

Installation instructions

Electrical requirements

The electrical voltage and frequency that is correct for this oven is stated on the serial number plate located inside the top vent. It is the customer responsibility to ensure that this oven is connected to the correct electrical supply.

If codes permit and a separate grounding wire is used, it is recommended that a qualified electrician determine that the grounding path and wire gauge is in accordance with local codes.

Do not use an extension cord with this appliance.

Double (OD302, OD302M) CAUTION!

The oven must be connected to a permanent and grounded supply.

Single (OS302, OS302M) Maximum current draw: 21 amps

Maximum Load:

5.1 kW

Double (OD302, OD302M)

Maximum current draw: 38.2 amps

Maximum Load:

9.2 kW

CONNECT OVEN WITH COPPER WIRE ONLY

The flexible armoured cable should be connected directly to the junction box.

Do not cut the conduit.

A U.L. listed conduit connector must be provided at the junction box.

Do not ground to a gas pipe.

Do not have a fuse in the grounding or neutral circuit.

Fuse both sides of the line.

A time delay fuse or circuit breaker is recommended. If using a time delay fuse, then fuse both sides of the line.

Flexible armoured cable from the appliance should be connected directly to the junction box.

Connect directly to the fused disconnect (or circuit breaker box) through flexible, armored or non-metallic sheathed, copper cable (with grounding wire).

Electrical connection

This oven is manufactured with white (neutral) power supply wire and a cabinet-connected green grounding wire taped together.

Feed the oven cable through the opening in the cabinet. Make the electrical connection following the steps appropriate for your installation.

CONNECT OVEN WITH COPPER WIRE ONLY WARNING

Electical Shock

Hazard

Disconnect the power supply before continuing.

Failure to do so may result in death or electrical shock.

1Disconnect the power supply.

2Remove the junction box cover.

3Connect the oven cable to the junction box through the U.L.-listed conduit connector.

4Connect the two black wires together with twist-on connectors.

5Connect the two red wires together with twist-on connectors.