Adjusting the minimum burner setting

Check whether the flame spreads to all burner ports when the burner is lit with the gas valve set to the minimum position. If some ports do not light, increase the minimum gas rate setting. Check whether the burner remains lit even when the gas valve is turned quickly from the maximum to the minimum position. If the burner does not remain lit, increase the minimum gas rate setting.

To adjust the minimum gas rate setting:

1Turn on the burner.

2Turn the valve to the MINIMUM position.

3 Take off the knob.

4 Using a small flat screwdriver, turn the screw (see Figs. 13 or 14) to the correct regulation.

Fig. 13 Adjusting the minimum burner setting: four-function models

GAS COOKTOP MODELS

Note: for LPG, the regulation screw is normally tightened up.

regulation screw

OR

regulation screw

Fig. 14 Adjusting the minimum burner setting: seven-function models (Note: valves may vary)

Table for the choice of injectors

 

Natural gas

 

LPG

 

 

 

 

 

 

 

Test Point Pressure [kPa]

 

1.0

 

2.75

 

 

 

 

 

 

 

 

Injector

 

Gas

Injector

 

Gas

BURNER

Orifice Dia.

 

Consumption

Orifice Dia.

 

Consumption

 

 

 

 

 

 

 

[mm]

 

[MJ/h]

[mm]

 

[MJ/h]

 

 

 

 

 

 

 

Auxiliary

0.85

 

3.60

0.53

 

3.60

 

 

 

 

 

 

 

Semi-rapid

1.12

 

6.30

0.70

 

6.30

 

 

 

 

 

 

 

Triple-ring wok

1.60

 

12.70

0.95

 

11.90

 

 

 

 

 

 

 