Contents
Programmable 10 MHz DDS Function Generator
Getting Started Manual
To register your product online, visit register.fluke.com
LIMITED WARRANTY AND LIMITATION OF LIABILITY
Safety
Getting Started Manual
The following symbols are used on the instrument and in this manual
Safety continued
Terminal connected to chassis ground Mains supply OFF Mains supply ON
Alternating current Warning - hazardous voltages may be present
Page
Emissions
EMC Compliance
Immunity
e EN61000-4-5 1995 Surge 0.5 kV line to line, 1 kV line to ground
Title
Table of Contents
AUX OUT
viii
Introduction
Getting Started
Before You Start
Mains Supply Voltage
Externally Applied Voltages
Getting Started
Controls and Connections
Figure 1. Model 271 Front Panel
shx0001f.gif
Controls
The Liquid Crystal Display
Function Keys
FIELD and DIGIT Keys and the Rotary Control
Numeric, Units and SET Keys
UTILITIES Keys
MODE Keys
OUTPUT Key
RECALL and REMOTE
EXT TRIG
Front Panel Inputs and Outputs
MAIN OUT
AUX OUT
CLOCK IN/OUT
Rear Panel Connectors
VCA IN
SYNC OUT
TRIG/SWEEP OUT
RS232 and GPIB Interface Connectors
Plug in and switch on the instrument
Using the Instrument
Starting up
Check the LCD Display
Set a frequency, for example 12.5 kHz
Generating Continuous Signals
FREQ=12.50000kHz VhiZ=+20.0 Vpp 50Ω DC=+0.00mV +0.00mV
SYM=50.0% 50.0%
Have a look at some other waveforms
Set the amplitude to +10 dBm
Change the dc offset
=80.00000us
DC OFFSET CHANGE * * BY OUTPUT LEVEL
Effect of the output attenuator
PER =80.00000us VhiZ=+4.00 Vpp 50Ω DC=+1.50 V +151.mV SYM=50.0% 50.0%
SOURCE=EXT TGEN=1.00ms 1.000kHz BURST COUNT= PHASE=+000 +000
Adjusting the phase
SOURCE=EXT TGEN=1.00ms 1.000kHz BURST COUNT= PHASE=+116 +116
Asymmetric waveforms
TRIG/SWEEP OUT signal
Generating Swept Signals
MODE=BEG-END LAW=LOG RAMP TIME=5.00 s TRIG SRC=CONTINUOUS MORE
MODE=BEG-END LAW=LOG RAMP TIME=0.05 s TRIG SRC=CONTINUOUS MORE
BEG FRQ=261.6000 Hz END FRQ=1.108700kHz MARK FRQ=523.3000 Hz MORE
PHASE=+000 +000
SOURCE=EXT TGEN=1.00ms 1.000kHz BURST COUNT=0001 PHASE=+000 +000
Generating a Triggered Burst
FREQ=2.000000kHz VhiZ=+20.0 Vpp 50Ω DC=+0.00mV +0.00mV
Special Waveforms
FSK Mode
Staircases
FREQ A=800.0000 Hz FREQ B=1.200000kHz SOURCE=TGEN FREE
Figure 2. 625-line PAL TV Signal
name
step
start µs
amplitude
VALS=ABS AUTO=YES STEP=08 ACTIVE LENGTH=0005 LEVEL=+153
VALS=ABS AUTO=YES STEP=01 ACTIVE LENGTH=0256 LEVEL=+000
Arbitrary Waveforms
Saving and Recalling Settings
RECALL ARB No SINX/X ENTER TO EXECUTE
RECALL ARB No ARB 03 IS EMPTY
Other Functions and Waveforms