12 Multimeter

USING MIN MAX FUNCTIONS

Recording Minimum and Maximum Reading with Elapsed Time

The MIN MAX with elapsed-time mode records the time (in hours and minutes) between when MIN MAX was entered and the last high and low was recorded. Time is kept to 99:59. OL is displayed for longer times.

1.To enable the MIN MAX elapsed-time clock, hold [j] down while moving the slide-switch from OFF to the volts or continuity/ohms position.

2.Insert the test leads, and put the meter in volts or ohms.

3.Connect the leads to the circuit.

4.Press [j] to select MIN MAX. j is displayed, and time is set to 00:00.

5.Press [j] to step through the display sequence shown in Figure 8.

6.To exit, press [j] for 2 seconds, or change the measurement function.