12Multimeter Us rs Manual

Function{

Range

Resolution

Accuracy (50 to 400 Hz)

 

4000 mV*

1 mV

±(1.9 %+3)

E

4.000

V

0.001 V

±(1.9 %+3)

40.00

V

0.01 V

±(1.9 %+3)

400.0

V

0.1 V

±(1.9 %+3)

600 V

 

1 V

±(1.9 %+3)

 

4000 mV*

1 mV

±(0.9 %+2)

 

4.000

V

0.001 V

±(0.9 %+2)

 

40.00

V

0.01 V

±(0.9 %+1)

 

400.0

V

0.1 V

±(0.9 %+1)

e

600 V

 

1 V

±(0.9 %+1)

 

400.0 Ω

0.1 Ω

±(0.9 %+2)

 

4.000 kΩ

0.001 kΩ

±(0.9 %+l)

 

40.00 kΩ

0.01 kΩ

±(0.9 %+1)

 

400.0 kΩ

0.1 kΩ

±(0.9 %+1)

 

4.000

MΩ

0.001 MΩ

±(0.9 %+1)

E

40.00 MΩ

0.01 MΩ

±(1.5 %+3)

 

1.000 pF

0.001 µF

±(1.9 %+2)

 

10.00

µF

0.01 µF

±(1.9 %+2)

 

100.0

µF

0.1 pF

±(1.9 %+2)

 

10000 pF

1.0 µF

î1000 µF ±(1.9 %+2)

MG

 

 

 

>1000 µF ±(10 % + 90) Typical

 

2.000

V

0.001 V

±(0.9 %+2) †

* The 4000 mV range can only be entered in manual range mode. Use the 4000 mV range with accessories.

The beeper is guaranteed to come on at <25 Ω and turn off at >250 Ω. The meter detects opens or shorts of 250 µs or longer.

26

Page 29
Image 29
Fluke PN 2063508 user manual Multimeter Us rs Manual