Franke Consumer Products FCR 908 TC manual Connections

Models: FCR 908 TC

1 52
Download 52 pages 8.5 Kb
Page 6
Image 6
Connections

Mounting the hood body

• Before attaching the hood body, tighten the two screws Vr located on

 

the hood body mounting points.

Vr

• Hook the hood body onto the screws 12a.

 

• Fully tighten support screws 12a.

 

• Adjust screws Vr to level the hood body.

 

• If necessary, it is possible to fasten the hood to the wall using more

12a

screws with wall plugs, which can be positioned from inside the hood

 

canopy.

 

Connections

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120 mm, the choice of which is left to the installer.

To install a ø 120 mm air exhaust connection, insert the re- ducer flange 9 on the hood body outlet.

Fix the pipe in position using sufficient pipe clamps (not sup- plied).

Remove any activated charcoal filters.

ø 150

ø 120

9

RECIRCULATION VERSION AIR OUTLET

Insert the connection extension pieces laterally 14.1 in connec- tion 15.

Insert the Connector 15 into the Support bracket 7.3 and fix it with a screw.

Make sure that the outlet of the extension pieces 14.1 is hori- zontally and vertically aligned with the chimney outlets.

Connect the air outlet connection 15 to the hood body outlet

using either a flexible or rigid pipe ø 150 mm, the choice of which is left to the installer.

• Ensure that the activated charcoal filters have been inserted.

7.3

14.1

 

15

 

 

ø 150

EN

 

6

 

6

Page 6
Image 6