Franke Consumer Products FDB 9078 SIL-K manual Hood body installation, Connections

Models: FDB 9078 SIL-K

1 14
Download 14 pages 20.96 Kb
Page 7
Image 7
Hood body installation

Hood body installation

Before hooking the hood body it is necessary to tighten 2 Vr screws placed in the fixing points of the body.

Hook the hood body on the 12a screws.

Tighten completely 12a support screws.

The correct hood body position can be levelled with Vr screws.

Fix the hood definitively by tightening the 12a security screws.

Connections

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120 mm, the choice of which is left to the installer.

To install a ø 120 mm air exhaust connection, insert the re- ducer flange 9 on the hood body outlet.

Fix the pipe in position using sufficient pipe clamps (not sup- plied).

Remove any activated charcoal filters.

AIR OUTLET - RECIRCULATION VERSION

Connect the Flange ø150 10 to the bottom end of the Connec- tor 15

Join the Hood canopy outlet to the Flange on the bottom part of the Connector, using a rigid or flexible pipe ø150 mm, selec- tion of which is at the discretion of the installation technician.

Make sure that the Activated charcoal odour filter has been fitted.

Vr

12a

ø 150

ø 120

9

15

10

ø 150

EN

 

7

 

7

Page 7
Image 7
Franke Consumer Products FDB 9078 SIL-K manual Hood body installation, Connections, Ducted Version Air Exhaust System