Franke Consumer Products FDB 9078 SIL-K manual Charcoal filter recycling version

Models: FDB 9078 SIL-K

1 14
Download 14 pages 20.96 Kb
Page 12
Image 12
Charcoal filter (recycling version)

Charcoal filter (recycling version)

This filter cannot be washed or regenerated. It must be replaced when the EF appears on the display or at least once every 4 months.

Activation of the alarm signal

In the recycling version hoods the filter saturation alarm must be activated during the instal- lation or later.

Switch off the hood and the lights.

Disconnect the hood from the mains supply.

When restoring the connection press and hold B-key.

When releasing the key two rotating rectangles appear on the display.

Within 3 seconds press the B-key until a flashing confirmation appears on the dispaly:

2 flashes with EF - charcoal filter saturation alarm ACTIVATED

1 flash with EF - charcoal filter saturation alarm DEACTIVATED.

REPLACING THE CHARCOAL FILTER

Reset of the alarm signal

• Switch off the hood and the lighting. If the 24h-function has been activated this has to be deactivated.

• Press the E-key until the display is unlit.

Replacing of the filter

• Open the comfort panels by pulling them downwards.

Remove the metal grease filters.

Remove the saturated charcoal filter by releasing the fixing hooks.

Fit the new filter and fasten it in its correct position.

Put the metal grease filters in their seats.

Close the comfort panels.

CHANGING THE SOUNDPROOFING ELEMENT

• Open the Comfort panels by pulling them.

• Remove the Metal grease filters.

• Remove the Activated charcoal filter, using the hooks pro- vided.

• Pull out the Soundproofing Element from below, pressing the side fins to disconnect it from the slot in the Hood Canopy.

• Clean it with a damp cloth and replace it, first making sure that it is completely dry.

Replace the Activated charcoal filters.

Replace the Metal grease filters.

Close the Comfort panels.

EN

 

1

 

12

Page 12
Image 12
Franke Consumer Products FDB 9078 SIL-K manual Charcoal filter recycling version, Activation of the alarm signal