Enterasys Networks 9034313-07 manual Set pwa initialize, Set pwa quietperiod

Models: 9034313-07

1 872
Download 872 pages 24.54 Kb
Page 822
Image 822

set pwa initialize

Usage

PWA will use a guest password and guest user name to grant network access with default policy privileges to users without established login names and passwords.

Example

This example shows how to enable PWA guest networking with RADIUS authentication:

C3(su)->set pwa guestnetworking authradius

set pwa initialize

Use this command to initialize a PWA port to its default unauthenticated state.

Syntax

set pwa initialize [port-string]

Parameters

port‐string

(Optional) Initializes specific port(s). For a detailed description of possible

 

port‐string values, refer to Port String Syntax Used in the CLI” on

 

page 7‐1.

 

 

Defaults

If port‐string is not specified, all ports will be initialized.

Mode

Switch command, read‐write.

Example

This example shows how to initialize ports ge.1.5‐7:

C3(su)->set pwa initialize ge.1.5-7

set pwa quietperiod

Use this command to set the amount of time a port will remain in the held state after a user unsuccessfully attempts to log on to the network.

Syntax

set pwa quietperiod time [port-string]

Parameters

time

Specifies quiet time in seconds.

port‐string

(Optional) Sets the quiet period for specific port(s). For a detailed

 

description of possible port‐string values, refer to Port String Syntax Used

 

in the CLI” on page 7‐1.

 

 

26-76 Authentication and Authorization Configuration

Page 822
Image 822
Enterasys Networks 9034313-07 Set pwa initialize, Set pwa quietperiod, This example shows how to initialize ports ge.1.5‐7