Enterasys Networks 9034313-07 manual Clear system temperature, Syslog enable, Disable

Models: 9034313-07

1 872
Download 872 pages 24.54 Kb
Page 81
Image 81

 

 

clear system temperature

Parameters

 

 

 

 

 

syslog enable

Enables or disables logging high temperature alerts to the system log

 

disable

when the system transitions into an alarm state.

 

 

 

 

trap enable disable

Enables or disables sending high temperature alerts by means of SNMP

 

 

traps when the system transitions into an alarm state.

 

 

 

 

overtemp‐threshold

Sets the thermal threshold as a percentage of the maximum rated for the

 

value

specific platform. Value can range from 0 to 100%.

 

 

 

Defaults

 

Syslog alerts are disabled by default.

Trap alerts are disabled by default.

Overtemp threshold is 100% by default.

Mode

Switch command, read‐write.

Usage

On the platforms that support this feature, temperature sensors are located in several different locations within the device. Threshold calibrations have been calculated separately for each platform. The thermal overtemp threshold is the high‐water mark that, when reached, triggers an alert to warn the system administrator that the device is operating at high temperatures.

When a high temperature alert condition occurs, the CPU LED on the front panel of the switch will flash red. In addition, if enabled, a syslog message will be logged and/or an SNMP trap will be sent.

The values set with this command can be viewed with the show system command.

Example

The following example enables sending SNMP traps and sets the overtemp threshold to 60%.

C3(su)->set system temperature trap enable overtemp-threshold 60

clear system temperature

Use this command to reset system high temperature parameters to their default values, on the platforms that support this feature.

Syntax

clear system temperature

Parameters

None.

Defaults

None.

SecureStack C3 Configuration Guide 3-19

Page 81
Image 81
Enterasys Networks 9034313-07 Clear system temperature, Syslog enable, Disable, Trap enable disable, Overtemp‐threshold