set linkflap downtime

Parameters

 

 

 

 

 

port‐string

Specifies the port(s) on which to set the link flap action trigger count.

 

 

 

 

threshold‐value

Specifies the number of link down transitions necessary to trigger the

 

 

link flap action. A minimum of 1 must be configured.

 

 

 

Defaults

 

 

None.

 

Mode

 

Switch mode, read‐write.

Example

This example shows how to set the link flap threshold on port ge.1.4 to 5.

C3(rw)->set linkflap threshold ge.1.4 5

set linkflap downtime

Use this command to set the time interval (in seconds) one or more ports will be held down after a link flap violation.

Syntax

set linkflap downtime port-string downtime-value

Parameters

port‐string

Specifies the port(s) on which to set the link flap downtime.

downtime‐value

Specifies a downtime in seconds. A value of 0 will set the downtime to

 

forever.

 

 

Defaults

None.

Mode

Switch mode, read‐write.

Example

This example shows how to set the link flap downtime on port ge.1.4 to 5000 seconds.

C3(rw)->set linkflap downtime ge.1.4 5000

clear linkflap down

Use this command to toggle link flap disabled ports to operational.

Syntax

clear linkflap down [port-string]

SecureStack C3 Configuration Guide 7-31