set summertime recurring

Mode

Switch command, read‐write.

Example

This example shows how to set a daylight savings time start date of April 4, 2004 at 2 a.m. and an ending date of October 31, 2004 at 2 a.m. with an offset time of one hour:

C3(su)->set summertime date April 4 2004 02:00 October 31 2004 02:00 60

set summertime recurring

Use this command to configure recurring daylight savings time settings. These settings will start and stop daylight savings time at the specified day of the month and hour each year and will not have to be reset annually.

Syntax

set summertime recurring start_week start_day start_month start_hr_min end_week end_day end_month end_hr_min [offset_minutes]

Parameters

start_week

Specifies the week of the month to restart daylight savings time. Valid

 

values are: first, second, third, fourth, and last.

 

 

start_day

Specifies the day of the week to restart daylight savings time.

 

 

start_hr_min

Specifies the time of day to restart daylight savings time. Format is

 

hh:mm.

 

 

end_week

Specifies the week of the month to end daylight savings time.

 

 

end_day

Specifies the day of the week to end daylight savings time.

 

 

end_hr_min

Specifies the time of day to end daylight savings time. Format is hh:mm.

 

 

offset_minutes

(Optional) Specifies the amount of time in minutes to offset daylight

 

savings time from the non‐daylight savings time system setting. Valid

 

values are 1 ‐ 1440.

 

 

Defaults

If an offset is not specified, none will be applied.

Mode

Switch command, read‐write.

Example

This example shows how set daylight savings time to recur starting on the first Sunday of April at

2 a.m. and ending the last Sunday of October at 2 a.m. with an offset time of one hour:

C3(su)->set summertime recurring first Sunday April 02:00 last Sunday October 02:00 60