Enterasys Networks 9034313-07 manual Set sflow receiver port, Clear sflow receiver, Maxdatagram

Models: 9034313-07

1 872
Download 872 pages 24.54 Kb
Page 857
Image 857

set sflow receiver port

sFlow Configuration

Mode

Switch command, read‐write.

Example

This example sets the maximum datagram size to 2800 bytes for index entry 1.

C3(su)->set sflow receiver 1 maxdatagram 2800

set sflow receiver port

Use this command to configure the UDP port on the sFlow Controller to which the switch will send sample datagrams.

Syntax

set sflow receiver index port port

Parameters

index

Index number in the sFlow Receivers Table for the receiver/Collector

 

being configured. The index can range from 1 to 8.

 

 

port port

Specifies the UDP port on the receiver/Collector to which the sample

 

datagrams should be sent. By default, the port is 6343.

 

 

Defaults

The default port value is 6343.

Mode

Switch command, read‐write.

Example

This example changes the sFlow receiver port on the Collector to 1234.

C3(su)->set sflow receiver 1 port 1234

clear sflow receiver

Use this command to delete a receiver/Collector from the sFlow Receivers Table, or to return certain parameters to their default values for the specified Collector.

Syntax

clear sflow receiver index [ip maxdatagram owner [timeout] port]

Parameters

index

Index number in the sFlow Receivers Table for the receiver/Collector

 

being configured. The index can range from 1 to 8.

 

 

ip

(Optional) Clear the IP address to 0.0.0.0. Sample datagrams are not sent

 

to Collectors with an IP address of 0.0.0.0.

 

 

maxdatagram

(Optional) Return the maximum datagram size to 1400 bytes.

 

 

SecureStack C3 Configuration Guide 28-9

Page 857
Image 857
Enterasys Networks 9034313-07 manual Set sflow receiver port, Clear sflow receiver, Default port value is, Maxdatagram