Enterasys Networks 9034313-07 manual Set sflow receiver owner, Set sflow receiver ip

Models: 9034313-07

1 872
Download 872 pages 24.54 Kb
Page 855
Image 855

set sflow receiver owner

sFlow Configuration

set sflow receiver owner

Use this command to configure the owner identity string and timeout value for an sFlow Collector in the switch’s sFlow Receivers Table.

Syntax

set sflow receiver index owner owner-stringtimeout timeout

Parameters

index

Index number in the sFlow Receivers Table for the receiver/Collector

 

being configured. The index can range from 1 to 8.

 

 

owner owner‐string

The identity string of the receiver/Collector being configured.

 

The string can be up to 127 characters in length.

 

 

timeout timeout

The time, in seconds, remaining before the receiver/Collector being

 

configured and all associated samplers and pollers expire.

 

The value can range from 0 to 4294967295 seconds.

 

 

Defaults

None.

Mode

Switch command, read‐write.

Usage

In order for an sFlow Collector to be assigned to receive sample datagrams from the sFlow Agent on the switch, an entry for that Collector must be configured in the switch’s sFlow Receivers Table. An entry must contain an owner identity string, a non‐zero timeout value, and the IP address of the Collector. Configure the IP address with the set sflow receiver ip command.

An entry without an owner identity string is considered unclaimed and cannot be assigned as a receiver to sampler or poller instances.

Once the timer set by this command expires, the receiver/Collector and all the samplers and pollers associated with this Collector expire and are removed from the switch’s configuration. In order to start sending sample data to the Collector again, the Collector must be reconfigured with a new timeout value and samplers and pollers must be configured again. Therefore, you should consider setting the timeout value to the largest value that is reasonable for your environment.

Example

This example configures an entry for index 1 in the sFlow Receivers Table.

C3(su)->set sflow receiver 1 owner ets1 timeout 180000

set sflow receiver ip

Use this command to configure the IP address of an sFlow Collector in the switch’s sFlow Receivers Table.

Syntax

set sflow receiver index ip ipaddr

SecureStack C3 Configuration Guide 28-7