sFlow Configuration

Commands

sFlow is disabled by default on SecureStack and G‐Series devices.

Example Configuration

The general procedure for configuring sFlow includes:

1.Configure your sFlow Collector information to be used by the sFlow Agent on the switch. Up to eight Collectors can be configured. The information is stored in the sFlowReceiverTable.

2.Enable and configure sFlow packet flow sampling instances on each port.

3.Enable and configure sFlow counter sampling poller instances on each port.

The following is an example of the commands used to configure sFlow:

#configure sFlow Collector 1

#accept defaults for datagram size and port

set sflow receiver 1 owner enterasys timeout 180000 set sflow receiver 1 ip 192.168.16.91

#

#configure packet sampling instances on ports 1 through 12 #assign to sFlow Collector 1

set sflow port ge.1.1-12 sampler 1

set sflow port ge.1.1-12 sampler maxheadersize 256 set sflow port ge.1.1-12 sampler rate 2048

#

#configure counter poller instances on ports 1 through 12 #assign to sFlow Collector 1

set sflow port ge.1.1-12 poller 1

set sflow port ge.1.1-12 poller interval 20

Commands

For information about...

Refer to page...

 

 

show sflow receivers

28-5

 

 

set sflow receiver owner

28-7

 

 

set sflow receiver ip

28-7

 

 

set sflow receiver maxdatagram

28-8

 

 

set sflow receiver port

28-9

 

 

clear sflow receiver

28-9

 

 

set sflow port poller

28-10

 

 

show sflow pollers

28-11

 

 

clear sflow port poller

28-12

 

 

set sflow port sampler

28-12

 

 

show sflow samplers

28-13

 

 

clear sflow port sampler

28-14